| Item
|
Descriptions |
4-20mA input |
Input impedance: 120 Ω
Regulation output resolution: 0.2 °
Three-phase triggering unbalance degree: < 0.6 ° |
Load mode |
50Hz three-phase 380VAC delta or star ( △ or Y) neutral point not grounding. Shift phase range: 0-150 ° |
50Hz three-phase 380VAC star (Y) neutral point grounding. Shift phase range: 0-175 ° |
50Hz three-phase 380VAC half control SCR. Shift phase range: 0-175 ° |
Isolated drive output |
8V crest value pulse. Each way can be connected with 4 SSR drives (two in serial and two in parallel) that have the same phase. Max drive current: < 30mA |
Wiring mode |
Three-phase three-wire system (ON), Three-phase four-wire system (OFF), chosen through a code switch |
Control mode |
Shift phase triggering, Cycle zero axial triggering, Contact input (ON: shift phase) |
Soft start/stop control |
ON: 0.2-120s (regulated through an internal resistor) |
OFF: 2s in soft start/soft stop |
LED director (5) state directive |
The LED director of red, of green and of yellow are the three-phase power supply director and the fast fuse director. RUN: green, STOP: yellow and ALM: red. |
Soft start/stop through an external servo switch: No voltage contact input. ON: Soft stop, and time: 3s (fixed). OFF: Soft start, and the time is set between 0.2s to 120s through an internal potentiometer P3 |
Over-temperature of 70 ℃ protection |
No voltage normally closed contact. The contact is open in over-temperature, and will be released in power-on again after the fault is overcome. |
Power Dissipation |
380VAC 50Hz 3W Fuse: 0.5A |
Discriminating phase |
Auto discriminating the phase of RST three-phase voltage, and the range of line voltage is 280-480VAC. |
Alarming relay |
A group of normally open/closed contacts (resistance load, 250VAC/ 1A ).
Alarming type: Open-phase and heat radiator over-temperature. |